Product technical description -
Hot Sales -
Moulded Case Circuit Breakers -
Circuit Breaker -
RCBO -
Circuit Breaker Blue Series -
Circuit Breaker M Series -
South Africa Modular Electrical Series -
Circuit Breaker Red Series -
Black Type Circuit Breaker -
South-east Asia Series -
Distribution Box -
Enclosure, Cabinet, Panel Board, Panel Cabinets, Distribution Board -
Piercing Connector -
ACB -
Other Circuit Breaker Type -
VCB -
WIFI Controller Circuit Breaker & Smart Home Products -
Surge Protective -
Explosion-proof Electrical -
Carbon Brush -
Power Fitting -
LED Lighting -
Inverter -
Timer -
Modular K.H.W. Meter -
Photo And Time Controls -
AC Contactor&Thermal Relay -
Switches -
Fuse -
Australia Products -
Wiring Accesories -
MCB Accessories -
Metallized Film For Capacitor -
Circuit Breakers Produce & Test Equipment -
Energy Meter -
Thermostat & Temperature Controller -
Surge Protective Device -
Vacuum Components -
Box Cover of Lighing Fitting -
Switches -
Industrial switch -
Power Supply -
Welder -
RCD protected -
Electric power -
new energy system: Solar system & inverter controller & battery -
Automatic Transfer Switch -
Weatherproof switches

APPLICATION
The basic parameters of the B2 series circuit breaker
Maximum voltage: 277VAC 50/60Hz,80VDC.
Current Level: 1A~5A.
Auxiliary Switch: SPDT,10.1A 250VAC, 0.5A 80VDC, 0.1A 125VAC.
Insulation Resistance 500VDC ,Minimum 100 megohms
Dielectric Strength: UL/CSA, in one minute on the condition of alternating , 1500V via the terminal
Life: Under condition of rated voltage and rated current the mechanical life is 10000times(6times every minute),the electric life is 6000 times
Trip-free: when overload, even if forced to keep the handle actuators in the ON position, the internal circuit breaker has been tripped.
Trip indication: when the overload, the actuators position the handle indication display OFF .when trip in the middle, and overload ,the actuators position handle in middle.
working environment: -40 ℃~+85℃
Install condition:when install , for the install panel screw please use 0.8-1.0NM .when the terminal connected,fo#8-32orM4 screw please use 1.4-1.7NM .For the #10-32orM5 screw,please use 1.7-2.3NM. As for the CB with 2or3 poles and more than 2 handles, the link rod、sleeve and retainer ring of the handle is in bulk.Please put the axis and sleeve on the handle,then put the retainer ring on each side. The product should install on horizontal, if you want vertical installation ,you need make spcial order
Poles: 1P、2P、3P.
Weight : about 65g/p
Standard: EN60934、UL1077、GB17701、UL489A、UL489.
Working performance : as follows.