序号 | 00 Item | 00 Unit | 00 Data | |||
1 | 额定电压 Bated yoltage | KV | 12 | |||
2 | 最高工作电压 Maximum operating voltage | KV | 12 | |||
3 | 额定电流 Rated Current | A | 630~1250 | 630~1600 | 630~1600 | |
4 | 额定短路开断电流 Rated short circuit breaking curent | KA | 20 | 25 | 31.5 | |
5 | 额定短路关合电流 Rated short-circuit switching current | KA | 50 | 63 | 80 | |
6 | 额定峰值耐受电流 Rated peak withstand current | KA | 50 | 63 | 80 | |
7 | 4S额定短路耐受电流 4S rated short-circuit withstand current | KA | 20 | 25 | 31.5 | |
8 | 额定绝缘水平 Rated insulation level | 工频耐压(额定开断前后) Power frequency voltage(rated breaking before and after) | KV | 42(fracture 48) | ||
冲击耐压(额定开断前后) Impulse withstand voltage(rated breaking before and after) | 75(fracture 85) | |||||
9 | 额定操作顺序 Rated operating sequence | 分-0.3S-合分-180S-合分 0-0.3S-CO-180S-CO | ||||
10 | 机械寿命 Mechanical life | Times | 10000 | |||
11 | 额定短路开断电流开断次数 Rated short-circuit current breaking times | Times | 50 | |||
12 | 操作机构额定合闸电压(直流) Rated Operating Mechanism Closing Voltage(DC) | v | AC、DC 110、220 | |||
13 | 操作机构额定分闸电压(直流) Rated Operating Mechanism Opening Voltage(DC) | V | AC、DC 110、220 | |||
14 | 触头开距 Contact opening distance | mm | 11±1 | |||
15 | 超行程(触头弹簧压缩长度) Overtravel(the length of contact spring compression) | mm | 3.5±0.5 | |||
16 | 三相分、合闸弹跳时间 Closing/Opening Time Difference Among Three Phase | ms | ≤2 | |||
17 | 触头合闸弹跳时间 Contact closing bounce time | ms | ≤2 | |||
18 | 平均分闸速度 Average opening speed | m/s | 0.9-1.2 | |||
19 | 平均合闸速度 Average closing speed | m/s | 0.5-0.8 | |||
20 | 分 闸 最 高 操 作 电 压 下 时 间 Maximum operating voltage | s | ≤0.05 | |||
Tripping Time | 最 低 操 作 电 压 下 Minimum operating voltage | ≤0.08 | ||||
21 | 合闸时间 Closing time | s | 0.1 | |||
22 | 各相主回路电阻 The main circuit resistance of each phase | 630≤501250≤451600≤40 | ||||
23 | 动静触头允许磨损累积厚度 Allowed Consumpted Thickness of Contacts | mm | 3 |
序号 | 00 Item | 00 Unit | 00 Data | |||
1 | 额定电压 Bated yoltage | KV | 12 | |||
2 | 最高工作电压 Maximum operating voltage | KV | 12 | |||
3 | 额定电流 Rated Current | A | 630~1250 | 630~1600 | 630~1600 | |
4 | 额定短路开断电流 Rated short circuit breaking curent | KA | 20 | 25 | 31.5 | |
5 | 额定短路关合电流 Rated short-circuit switching current | KA | 50 | 63 | 80 | |
6 | 额定峰值耐受电流 Rated peak withstand current | KA | 50 | 63 | 80 | |
7 | 4S额定短路耐受电流 4S rated short-circuit withstand current | KA | 20 | 25 | 31.5 | |
8 | 额定绝缘水平 Rated insulation level | 工频耐压(额定开断前后) Power frequency voltage(rated breaking before and after) | KV | 42(fracture 48) | ||
冲击耐压(额定开断前后) Impulse withstand voltage(rated breaking before and after) | 75(fracture 85) | |||||
9 | 额定操作顺序 Rated operating sequence | 分-0.3S-合分-180S-合分 0-0.3S-CO-180S-CO | ||||
10 | 机械寿命 Mechanical life | Times | 10000 | |||
11 | 额定短路开断电流开断次数 Rated short-circuit current breaking times | Times | 50 | |||
12 | 操作机构额定合闸电压(直流) Rated Operating Mechanism Closing Voltage(DC) | v | AC、DC 110、220 | |||
13 | 操作机构额定分闸电压(直流) Rated Operating Mechanism Opening Voltage(DC) | V | AC、DC 110、220 | |||
14 | 触头开距 Contact opening distance | mm | 11±1 | |||
15 | 超行程(触头弹簧压缩长度) Overtravel(the length of contact spring compression) | mm | 3.5±0.5 | |||
16 | 三相分、合闸弹跳时间 Closing/Opening Time Difference Among Three Phase | ms | ≤2 | |||
17 | 触头合闸弹跳时间 Contact closing bounce time | ms | ≤2 | |||
18 | 平均分闸速度 Average opening speed | m/s | 0.9-1.2 | |||
19 | 平均合闸速度 Average closing speed | m/s | 0.5-0.8 | |||
20 | 分 闸 最 高 操 作 电 压 下 时 间 Maximum operating voltage | s | ≤0.05 | |||
Tripping Time | 最 低 操 作 电 压 下 Minimum operating voltage | ≤0.08 | ||||
21 | 合闸时间 Closing time | s | 0.1 | |||
22 | 各相主回路电阻 The main circuit resistance of each phase | 630≤501250≤451600≤40 | ||||
23 | 动静触头允许磨损累积厚度 Allowed Consumpted Thickness of Contacts | mm | 3 |