Availability: | |
---|---|
America
Type and meaning
1、Enterprise Code: Haohui Electronics
2、Serial Number
3、Number of contact groups: one、two
4、H-normally open contact Contact Form: Z-conversion type D-normally closed contact
5、mounted type: P:PCB mounted type No Letters: plug-in moudted
6、operating state:L:LED indicate No Letters:no indicate
7、auxiliary, function : T-Cover plate type G-mechanical indicate D/CR-Inhibitory protection
8、Coil Voltage:DCis for direct voltage AC is for alternating voltage
Product performance
Contact parameters | Contact Form | 1Z,1H,1D 2Z,2H,2D | |
Contact load | 12A/250VAC,30VDC 8A/250VAC,30VDC | ||
Switching power | 3000VA,360W 2000VA,240W | ||
Contact Resistance | ≤100mΩ | ||
Contact Materia | Ag alloy | ||
Ele ctrical life | 1×10⁵ | ||
Mechanical life | AC:3×106 DC:5×106 | ||
Pick -up Voltage | DC:≤75%,AC:≤80%50/60Hz | ||
Drop-out Voltage | DC:≥10%,AC:≥30%50/60Hz | ||
Max Voltage | 110% | ||
Coil voltage | DC (W) | 0.53 | |
AC(VA | 0.9 | ||
Suction time | ≤20ms | ||
Release time | AC | ≤20ms | |
DC | ≤10ms | ||
Insulation Resistance | ≥1000MΩ (500VDC) | ||
Dielectric Strength | Between the same pole contacts | 1200VAC/1min(Leakage current) | |
Between polar contacts | 1500VAC/1min(Leakage current) | ||
Between contact and coil | 2500VAC/1min(Leakage current) | ||
Ambient temperature | -25℃+55℃ | ||
Ambient humidity | 5%~85%RH | ||
Atmospheric pressure | 86~106KPa | ||
Impact resistance | 10G(Sine half wave pulse:11ms) | ||
Vibration resistance | 10~55Hz Double amplitude:1.0mm | ||
mounted type | plug-in moudted | ||
weight | around 20g |
External dimensions (mm)
Wiring diagram
Type and meaning
1、Enterprise Code: Haohui Electronics
2、Serial Number
3、Number of contact groups: one、two
4、H-normally open contact Contact Form: Z-conversion type D-normally closed contact
5、mounted type: P:PCB mounted type No Letters: plug-in moudted
6、operating state:L:LED indicate No Letters:no indicate
7、auxiliary, function : T-Cover plate type G-mechanical indicate D/CR-Inhibitory protection
8、Coil Voltage:DCis for direct voltage AC is for alternating voltage
Product performance
Contact parameters | Contact Form | 1Z,1H,1D 2Z,2H,2D | |
Contact load | 12A/250VAC,30VDC 8A/250VAC,30VDC | ||
Switching power | 3000VA,360W 2000VA,240W | ||
Contact Resistance | ≤100mΩ | ||
Contact Materia | Ag alloy | ||
Ele ctrical life | 1×10⁵ | ||
Mechanical life | AC:3×106 DC:5×106 | ||
Pick -up Voltage | DC:≤75%,AC:≤80%50/60Hz | ||
Drop-out Voltage | DC:≥10%,AC:≥30%50/60Hz | ||
Max Voltage | 110% | ||
Coil voltage | DC (W) | 0.53 | |
AC(VA | 0.9 | ||
Suction time | ≤20ms | ||
Release time | AC | ≤20ms | |
DC | ≤10ms | ||
Insulation Resistance | ≥1000MΩ (500VDC) | ||
Dielectric Strength | Between the same pole contacts | 1200VAC/1min(Leakage current) | |
Between polar contacts | 1500VAC/1min(Leakage current) | ||
Between contact and coil | 2500VAC/1min(Leakage current) | ||
Ambient temperature | -25℃+55℃ | ||
Ambient humidity | 5%~85%RH | ||
Atmospheric pressure | 86~106KPa | ||
Impact resistance | 10G(Sine half wave pulse:11ms) | ||
Vibration resistance | 10~55Hz Double amplitude:1.0mm | ||
mounted type | plug-in moudted | ||
weight | around 20g |
External dimensions (mm)
Wiring diagram