Applications
· Industrical control systems, air-conditioning system.
· Applied to the electrical control circuit, connected by a predetermined time or breaking the circuit, and indicates that the circuit status.
Function Features
· Compact in size, with a width of only 18mm that can be mounted onto 35mm DIN rail.
·A wide time delay range of 0.1s…100h.
· Repeatable accuracy ≤0.2%.
· Built-in high-performance microcontroller with strong resistance to interference and high reliability.
· Various rated supply voltage specifications available.
· LED indicator lamp indicates “power ON”and “time delay”states.
Technical Parameters
| Rated control supply voltage | 12VDC,24VDC |
| 110VAC,220VAC,380VAC 50/60Hz | |
| 24V..240V AC/DC 50/60Hz | |
| Allowable fluctuation range:±10% | |
| Rated insulation voltage | AC380V |
| Rated power consumption | AC:≤1.5VA DC≤1W |
| Range of time delay | 0.1s..100h(selection through knob) |
| Setting accuracy | ≤5% |
| Repeatable accuracy | ≤0.2% |
| Power-up repetition interval | ≥200ms |
| Electrical life | 100000 cycles |
Technical Parameters
| Mechanical life | 1000000 cycles |
| Conventional heat current | 5A |
| Utilisation category | AC-15 |
| Contact capacity | AC-15: Ue/le AC240V/1.5A AC380V/0.95A |
| Altitude | ≤2000m |
| Protection degree | IP20 |
| Pollution degree | 3 |
| Operation temperature | -5..40℃ |
Function Features
· Compact in size, with a width of only 18mm that can be mounted onto 35mm DIN rail.
·A wide time delay range of 0.1s…100h.
· Repeatable accuracy ≤0.2%.
· Built-in high-performance microcontroller with strong resistance to interference and high reliability.
· Various rated supply voltage specifications available.
· LED indicator lamp indicates “power ON”and “time delay”states.
Technical Parameters
| Rated control supply voltage | 12VDC,24VDC |
| 110VAC,220VAC,380VAC 50/60Hz | |
| 24V..240V AC/DC 50/60Hz | |
| Allowable fluctuation range:±10% | |
| Rated insulation voltage | AC380V |
| Rated power consumption | AC:≤1.5VA DC≤1W |
| Range of time delay | 0.1s..100h(selection through knob) |
| Setting accuracy | ≤5% |
| Repeatable accuracy | ≤0.2% |
| Power-up repetition interval | ≥200ms |
| Electrical life | 100000 cycles |
Technical Parameters
| Mechanical life | 1000000 cycles |
| Conventional heat current | 5A |
| Utilisation category | AC-15 |
| Contact capacity | AC-15: Ue/le AC240V/1.5A AC380V/0.95A |
| Altitude | ≤2000m |
| Protection degree | IP20 |
| Pollution degree | 3 |
| Operation temperature | -5..40℃ |