| Name | argument | |
|---|---|---|
Basic index | dimension | 85mm (H) ×226mm (W) ×4390mm (D) |
| weight | ≤11kg | |
| Efficiency (full load) | >95.5% | |
| Standby power consumption | < 8W | |
| Heat dissipation mode | Forced air cooling | |
| Pilot lamp | Green: normal running Yellow: protection alarm Red: fault alarm | |
| Number of parallel machines | ≤60 | |
Input characteristic | Input voltage | 285Vac-475Vac, three-phase + protected area |
| Input current | <40A | |
| Grid frequency | 45Hz ~ 65Hz | |
| Power factor | ≥0.99 | |
| ITHD | ≤5% |
Output characteristic | Output power | 20kW@ Output voltage ≥300Vdc |
| Voltage range | 50Vdc to 750Vdc. The default value is 200vdc | |
| Current range | 0A ~ 50A | |
| Voltage regulation accuracy | ≤±0.5% | |
| Unbalance degree of current equalization | ≤±5% |
Environmental condition | Operating temperature | The range from -40° C to +75° C is not derated at 60° C |
| Storage temperature | - 40°℃ ~ + 75°℃ | |
| Relative humidity | ≤ 95%RH, no condensation | |
| altitude | No derating is required for <2000m. >1000m Set the actual altitude. The operating temperature decreases by 1° for every 100m increase | |
| MTBF | >500,000 hours |
Alarm and protection | Input overvoltage or undervoltage | Shutdown can restore visual movement |
| Output overvoltage | Shutdown can restore visual movement | |
| Overcurrent and short circuit | Shutdown can restore visual movement | |
| Vovertemperature | Shutdown can restore visual movement |
| Name | argument | |
|---|---|---|
Basic index | dimension | 85mm (H) ×226mm (W) ×4390mm (D) |
| weight | ≤11kg | |
| Efficiency (full load) | >95.5% | |
| Standby power consumption | < 8W | |
| Heat dissipation mode | Forced air cooling | |
| Pilot lamp | Green: normal running Yellow: protection alarm Red: fault alarm | |
| Number of parallel machines | ≤60 | |
Input characteristic | Input voltage | 285Vac-475Vac, three-phase + protected area |
| Input current | <40A | |
| Grid frequency | 45Hz ~ 65Hz | |
| Power factor | ≥0.99 | |
| ITHD | ≤5% |
Output characteristic | Output power | 20kW@ Output voltage ≥300Vdc |
| Voltage range | 50Vdc to 750Vdc. The default value is 200vdc | |
| Current range | 0A ~ 50A | |
| Voltage regulation accuracy | ≤±0.5% | |
| Unbalance degree of current equalization | ≤±5% |
Environmental condition | Operating temperature | The range from -40° C to +75° C is not derated at 60° C |
| Storage temperature | - 40°℃ ~ + 75°℃ | |
| Relative humidity | ≤ 95%RH, no condensation | |
| altitude | No derating is required for <2000m. >1000m Set the actual altitude. The operating temperature decreases by 1° for every 100m increase | |
| MTBF | >500,000 hours |
Alarm and protection | Input overvoltage or undervoltage | Shutdown can restore visual movement |
| Output overvoltage | Shutdown can restore visual movement | |
| Overcurrent and short circuit | Shutdown can restore visual movement | |
| Vovertemperature | Shutdown can restore visual movement |